[Feb 08, 2022] Get New H19-338-ENU Certification Practice Test Questions Exam Dumps [Q77-Q98]

Share

[Feb 08, 2022] Get New H19-338-ENU Certification Practice Test Questions Exam Dumps

Real H19-338-ENU Exam Dumps Questions Valid H19-338-ENU Dumps PDF

NEW QUESTION 77
Huawei active-active (HyperMetro) solution must use Huawei UltraPath.

  • A. True
  • B. False

Answer: B

 

NEW QUESTION 78
FastWrite improves performance by 30%.
How many kilometers between active-active data centers can this improvement be applied to? (Multiple choice)

  • A. 100 km
  • B. 0 km
  • C. 50 km
  • D. 20 km

Answer: A,C

 

NEW QUESTION 79
The full-stripe write technology supported by Dorado can effectively improve SSDs' service life.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 80
Which reliability technologies are used in Huawei all-flash storage? (Multiple choice)

  • A. Power failure protection
  • B. Bad block management
  • C. RAID
  • D. Wear leveling

Answer: B,C,D

 

NEW QUESTION 81
The system availability is 99.999%, indicating that the annual interruption time of the storage array is about 5 minutes.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 82
Which statement about the ROW technology for OceanStor V5 is true?

  • A. One of the advantages of ROW is that it does not easily generate data fragments
  • B. ROW-based snapshots do not have extra data copies, and therefore the performance is better.
  • C. Block snapshots use the ROW technology

Answer: B

 

NEW QUESTION 83
HyperCDP objects can be used to restore data but cannot be directly mapped to hosts for read and write operations.

  • A. True
  • B. False

Answer: B

 

NEW QUESTION 84
Huawei HyperMetro (active-active) solution supports non-disruptive capacity expansion.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 85
HyperMetro uses the quorum server mode. If all replication links between two sites are down, which site survives and continues providing services>

  • A. The site that wins the arbitration
  • B. Preferred site
  • C. Non-preferred site

Answer: B

 

NEW QUESTION 86
What are the benefits of intelligent DAEs? (Multiple choice)

  • A. Accelerated data reconstruction
  • B. Reduced impact on services during data reconstruction
  • C. Improved storage performance
  • D. Reduced power consumption

Answer: A,B,C

 

NEW QUESTION 87
Which of the following specifications is correct for NVMe disk enclosures (Intellegent DAE)?

  • A. 36 disks per 2U
  • B. 36 disks per 1U
  • C. 25 disks per 1U
  • D. 25 disks per 2U

Answer: A

 

NEW QUESTION 88
Which of the following chips are part of the Dorado V6 in addition to Dorado V3's self-developed chips? (Multiple choice)

  • A. CPU chip
  • B. BMC chip
  • C. AI chip
  • D. SSD controller chip
  • E. Multi-protocol interface chip

Answer: A,B,C,D,E

 

NEW QUESTION 89
Which statements are true about the benefits of deduplicatin and compression provided by FusionStorage? (Multiple choice)

  • A. Extending the SSD service life.
  • B. Reducing the initial storage purchase cost.
  • C. Saving storage space.
  • D. Reducing the TCO

Answer: B,C,D

 

NEW QUESTION 90
What is the purpose of using sequential I/Os to overwrite all LUNs before testing Dorado performance?

  • A. To ensure that all space of thin LUNs is allocated so read performance is close to that in actual scenarios
  • B. To ensure correct deduplication and compression ratios
  • C. To provide better performance

Answer: C

 

NEW QUESTION 91
OceanStor 100D uses NVDIMMs as cache, which can prevent data loss during power failure.

  • A. Yes
  • B. No

Answer: A

 

NEW QUESTION 92
Which is the scale-out networking protocol that OceanStor Dorado V6 supports?

  • A. FC
  • B. PCIe
  • C. RoCE
  • D. IB

Answer: C

 

NEW QUESTION 93
Which technology can achieve zero RPO?

  • A. Clone
  • B. Snapshots
  • C. Asynchronous replication
  • D. Active-active

Answer: D

 

NEW QUESTION 94
What are the highlights of Huawei's HyperMetro NAS solution? (Multiple choice)

  • A. FastWrite is supported.
  • B. The active-active (HyperMetro) solution can be smoothly upgraded to the geo-redundant 3DC DR solution.
  • C. The dual-arbitration mode is provided.
  • D. Cross-site bad block repair is supported.
  • E. No additional gateways are required.

Answer: A,B,C,D,E

 

NEW QUESTION 95
What are the typical networking modes of a FusionStorage cluster? (Multiple choice)

  • A. Integrated front-end and back-end storage network.
  • B. Isolated front-end and back-end storage networks.
  • C. TCP/IP, InfiniBand, and RoCE networks.

Answer: A,B,C

 

NEW QUESTION 96
Which functions does SmartQoS provide on OceanStor Dorado V6? (Multiple choice)

  • A. LUN prioriy
  • B. Maximum IOPS
  • C. Maximum bandwidth
  • D. Latency control

Answer: B,C

 

NEW QUESTION 97
In database application scenarios, which is the recommended latency of the active-active (HyperMetro) replication network?

  • A. 0.5
  • B. 0
  • C. 1
  • D. 2

Answer: C

 

NEW QUESTION 98
......

H19-338-ENU Exam Dumps - PDF Questions and Testing Engine: https://www.vceengine.com/H19-338-ENU-vce-test-engine.html

Latest H19-338-ENU Exam Dumps for Pass Guaranteed: https://drive.google.com/open?id=1pIcbmXIm-0XSRtLheJRIv25njRpV1j-_