Get Started CFPS Exam [2025] Dumps NFPA PDF Questions [Q85-Q109]

Share

Get Started: CFPS Exam [2025] Dumps NFPA PDF Questions

CFPS Premium Exam Engine pdf Download

NEW QUESTION # 85
What is one potential means for dispersing a chemical agent over a wide area?

  • A. Steam radiators
  • B. 55-gallon drums
  • C. Crop-dusting aircraft
  • D. Railway tank cars

Answer: A


NEW QUESTION # 86
Which type of roof covering is most effective in preventing the spread of fires from flying brands?

  • A. Class C
  • B. Class B
  • C. Class A
  • D. Class D

Answer: C

Explanation:
Class A roof coverings are the most effective in preventing the spread of fires from flying brands. Flying brands are burning embers or pieces of combustible material that are carried by the wind and can ignite other combustible materials or structures. Class A roof coverings are tested to withstand severe fire exposure from simulated fire sources, such as large burning brands, and do not produce flying brands themselves. Class A roof coverings include materials such as asphalt shingles, metal sheets, clay or concrete tiles, slate, and some types of synthetic membranes12. Reference:
Class A, B, and C Roof Ratings - UL
Fire-Resistant Roofs - Fire Safe Marin


NEW QUESTION # 87
Semiconductor manufacturing plants have several potential hazards that are not widely encountered in other industries including toxic materials, radio frequency fields, ionizing radiation, and:

  • A. hot work
  • B. flammable liquids
  • C. pyrophoric gases
  • D. electrical

Answer: A

Explanation:
http://www2.iccsafe.org/states/seattle/seattle_fire/pdfs/chapter%2018.pdf


NEW QUESTION # 88
Requirements for the installation, operation, and maintenance of electrical emergency system circuits and equipment are given in the National Electrical Code (NEC).

  • A. Article 600
  • B. Article 700
  • C. Article 800
  • D. Article 500

Answer: D

Explanation:


NEW QUESTION # 89
Which of the following would NOT be an appropriate purpose for employing a guard service to protect a property against fire loss?

  • A. To facilitate and control the movement of persons into, out of, and within the property
  • B. To carry out procedures for the orderly conduct of some operations on the property
  • C. To protect the property at times when the management is not present
  • D. To perform routine housekeeping and equipment maintenance operations during nonproduction hours

Answer: D

Explanation:
The correct answer is C. To perform routine housekeeping and equipment maintenance operations during nonproduction hours would NOT be an appropriate purpose for employing a guard service to protect a property against fire loss. A guard service is typically hired to provide security and protection for a property, not to perform other tasks that are unrelated to fire prevention or control. Housekeeping and equipment maintenance operations should be done by qualified and authorized personnel who are trained and equipped to handle any potential fire hazards. A guard service may not have the necessary skills, tools, or authority to perform these operations safely and effectively. Moreover, these operations may interfere with the guard service's primary duty of monitoring and patrolling the property for any signs of fire or intrusion12345


NEW QUESTION # 90
What type of process hazard analysis program addresses the prevention of flammable and hazardous materials released from containment?

  • A. Process safety
  • B. Fault tree
  • C. Mechanical integrity
  • D. Management of change

Answer: A

Explanation:
Process safety is the type of process hazard analysis program that addresses the prevention of flammable and hazardous materials released from containment. Process safety is a discipline that focuses on the prevention and control of incidents that have the potential to cause catastrophic consequences involving fire, explosion, or toxic release. Process safety involves the application of engineering and management principles, criteria, and techniques to identify, understand, and control process hazards. Process safety covers many aspects of a process, such as design, operation, maintenance, inspection, testing, and emergency response.


NEW QUESTION # 91
The minimum required fire flow for manual fire suppression is based upon type or construction square footage of the building and______.

  • A. Occupancy classification
  • B. Presence or lack of sprinklers
  • C. Hazard Classification
  • D. Presence or lack of standpipes

Answer: A


NEW QUESTION # 92
The goals of the first edition of NFPA 13D were to provide sufficient time for safe egress or rescue, economic viability, and

  • A. prevent flashover.
  • B. limit water damage.
  • C. limit damage to the dwelling.
  • D. alert the fire department.

Answer: C

Explanation:
the goals of the first edition of NFPA 13D were to provide sufficient time for safe egress or rescue, economic viability, and limit damage to the dwelling. The first edition of NFPA 13D was published in 1975 and was based on the concept of a "life safety" sprinkler system that was intended to protect the occupants of one- and two-family dwellings and manufactured homes from fire. The first edition of NFPA 13D stated that the system was not designed to protect the property or contents from fire damage, but rather to provide a tenable environment for escape or rescue 1. The first edition of NFPA 13D also recognized the need for economic viability of the system, and therefore allowed for reduced water supply and piping requirements compared to other sprinkler standards 2. The first edition of NFPA 13D did not explicitly state the goal of limiting damage to the dwelling, but it implied that the system would have some beneficial effect on the fire spread and severity by stating that the system was designed to prevent flashover in the room of fire origin 1. Reference:
NFPA 13D: Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, 1975 Edition, Section 1-1 1 Fire Protection Handbook, 20th Edition, Volume 1, Chapter 8, Section 8.2.1.2 2


NEW QUESTION # 93
What is the maximum allowable quantity per control area for a nonliquified oxidizing gas stored in a gas cabinet in an unsprinklered area?

  • A. 1000 ft3 (28 m3)
  • B. 2000 ft3 (56 m3)
  • C. 3000 ft3 (85 m3)
  • D. 1500 ft3 (43 m3)

Answer: B

Explanation:
According to NFPA 400, Table 5.2.1.1.3, the maximum allowable quantity (MAQ) of a nonliquified oxidizing gas per control area in an unsprinklered area is 2000 ft3 (56 m3) when stored in a gas cabinet. This quantity can be increased by 100% if the area is sprinklered or by 300% if the area is also provided with a gas detection system. A gas cabinet is a ventilated enclosure for the storage of one or more compressed gas containers that provides a method of control for potential leakage or fire exposure hazards [NFPA 400, 3.3.32]. Reference: NFPA 400, Table 5.2.1.1.3; NFPA 400, 3.3.32; NFPA 400, 5.2.1.1.3.1; NFPA 400, 5.2.1.1.3.2.


NEW QUESTION # 94
An oxygen enriched atmosphere is defined as any atmosphere in which the concentration of oxygen exceeds 21% by volume or the partial pressure of the oxygen exceeds what pressure?

  • A. 16 KpA
  • B. 16 Atmospheres
  • C. 160 TORR
  • D. 1.6 psi

Answer: D


NEW QUESTION # 95
The room-corner test is used 10 assess________.

  • A. Interior finish materials
  • B. Exterior materials
  • C. Roofing materials
  • D. Floor finishes

Answer: A


NEW QUESTION # 96
Which of the following approaches can be used to manage smoke in large that consists of allowing smoke to till the large volume space while occupants evacuate the atrium?

  • A. Unsteady clear height
  • B. Smoke filling
  • C. Steady clear height
  • D. Forced filling

Answer: C


NEW QUESTION # 97
Which of the following is a device constructed of a pair of wire of different metals or alloys welded together at a point to form a junction and calibrated to give the temperature in degrees?

  • A. Pyrometer
  • B. Resistance thermometer
  • C. Liquid expansion thermometer
  • D. Thermocouple

Answer: C


NEW QUESTION # 98
NFPA 25 requires initial testing of representative samples of fast response sprinklers after

  • A. 50 years.
  • B. 5 years.
  • C. 10 years.
  • D. 20 years.

Answer: D

Explanation:
Explanation
20 years.
According to NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2020 edition, fast response sprinklers are those that have a response time index (RTI) of 50 (m s)^(1/2) or less.These sprinklers are designed to activate faster than standard response sprinklers in the event of a fire, and they are typically used in light hazard, ordinary hazard, and residential occupancies1 NFPA 25 requires initial testing of representative samples of fast response sprinklers after 20 years from the date of manufacture, and subsequent testing every 10 years thereafter. The testing involves removing a minimum of four sprinklers or 1% of the total number of sprinklers per individual sprinkler sample, whichever is greater, and sending them to a recognized testing laboratory. The laboratory will perform a plunge test, which measures the time it takes for the sprinkler to operate when exposed to a specified air temperature.The test results will indicate whether the sprinklers meet the acceptance criteria or need to be replaced123 References:
NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems1 Sprinkler System Inspections, Testing, and Maintenance Frequencies Explained | NFPA4 Sprinkler Testing on Quick Response Sprinklers: What You Need to Know2 NFPA 25 ITM Quick Reference Guide - hillgrp.com3


NEW QUESTION # 99
Wn.cn class of fire-retardant roof coverings are effective against light fire exposures, and afford at least a slight degree of fire protection to the root decks?

  • A. Class D coverings
  • B. Class C coverings
  • C. Class A coverings
  • D. Class B coverings

Answer: B


NEW QUESTION # 100
When using the Fire Safety Concept Tree to assess life safety for occupancies, the major categories of strategies include managing the fire, managing exposed occupants, and

  • A. risk classification.
  • B. occupant notification.
  • C. fire prevention.
  • D. emergency response.

Answer: D

Explanation:
The Fire Safety Concept Tree is a tool for systematically evaluating the fire safety performance of a building or occupancy. It consists of three main branches: fire prevention, fire protection, and fire safety management. Fire prevention aims to eliminate or reduce the occurrence of fire. Fire protection aims to control or limit the fire development and spread, and to protect the exposed occupants and property. Fire safety management aims to ensure the effective operation and maintenance of the fire safety systems and the appropriate human behavior in case of fire. Emergency response is one of the subcategories of fire protection, which includes the actions of the fire department, the building staff, and the occupants to respond to the fire emergency. Reference:


NEW QUESTION # 101
A building with sleeping rooms rented to 16 or fewer people on either a transient or permanent basis, with or without meals, but without separate cooking facilities for individual occupants is what type of occupancy?

  • A. Hotel
  • B. Dormitory
  • C. Lodging and rooming
  • D. Apartment

Answer: A

Explanation:
Lodging or Rooming House. A building or portion thereof that does not qualify as a one- or two-family dwelling, that provides sleeping accommodations for a total of 16 or fewer people on a transient or permanent basis, without personal care services, with or without meals, but without separate cooking facilities for individual occupants.


NEW QUESTION # 102
The maximum discharge time permitted for halocarbon clean agent systems is:

  • A. 10 seconds
  • B. 30 seconds
  • C. 5 seconds
  • D. 60 seconds

Answer: C


NEW QUESTION # 103
When using water mist as an extinguishing mechanism, the effectiveness of a fine mist depends on

  • A. the momentum and direction of the spray relative to the fire.
  • B. the ability of the mist to directly spray on the fire.
  • C. how much conductive heat the mist system will absorb.
  • D. how much mist diverts to the compartment boundaries.

Answer: A

Explanation:
Explanation
When using water mist as an extinguishing mechanism, the effectiveness of a fine mist depends on the momentum and direction of the spray relative to the fire. The momentum and direction of the spray determine how well the mist can penetrate the fire plume and reach the flame zone, where the mist droplets can evaporate and cool the fire, displace oxygen, and dilute the fuel vapors. The mist spray should have sufficient momentum to overcome the buoyancy and entrainment of the fire plume, and the direction of the spray should be aligned with the fire plume to avoid deflection and dispersion. The ability of the mist to directly spray on the fire, how much mist diverts to the compartment boundaries, and how much conductive heat the mist system will absorb are not the main factors affecting the extinguishing effectiveness of a fine mist.
References:Water Mist Systems Overview | NFPA;Engineering Relations for Water Mist Fire Suppression Systems;Effectiveness of Swirl Water Mist Nozzles for Fire Suppression


NEW QUESTION # 104
Environmental Protection Agency standards require solid waste be treated as hazardous if it is a listed waste and/or meets the characteristics prescribed by the standard for toxicity, reactivity, corrosivity, and

  • A. compactability.
  • B. treatability.
  • C. solubility.
  • D. ignitability.

Answer: D

Explanation:
The correct answer is C. Environmental Protection Agency (EPA) standards require solid waste be treated as hazardous if it is a listed waste and/or meets the characteristics prescribed by the standard for toxicity, reactivity, corrosivity, and ignitability. A listed waste is a waste that appears on one of the four lists of hazardous wastes in the Code of Federal Regulations (CFR) part 261 subpart D1. A characteristic waste is a waste that exhibits one or more of the following traits: toxicity, reactivity, corrosivity, or ignitability2. Toxicity is the ability of a waste to leach harmful chemicals into the environment. Reactivity is the tendency of a waste to undergo violent chemical reactions or generate toxic gases. Corrosivity is the property of a waste to corrode metals or damage living tissues. Ignitability is the capacity of a waste to catch fire under certain conditions2. These characteristics are defined by specific tests and criteria in the CFR part 261 subpart C3. The EPA standards for hazardous waste are based on the Resource Conservation and Recovery Act (RCRA), which is the federal law that regulates the management of solid and hazardous waste in the United States4.


NEW QUESTION # 105
Which system contains actionable information about an incident involving, or a threat targeting, critical national networks or infrastructures?

  • A. Homeland Security Information Bulletins
  • B. Color-coded threat-level system
  • C. Homeland Security Advisory System
  • D. Homeland Security Threat Advisories

Answer: C


NEW QUESTION # 106
Which factor plays a significant role in most industrial fire and explosion losses?

  • A. Human
  • B. Mechanical
  • C. Process
  • D. External

Answer: A

Explanation:
The answer is C. Human factor plays a significant role in most industrial fire and explosion losses. According to a study by Allianz Global Corporate & Specialty (AGCS), human error is the cause of 80% of all industrial accidents, including fires and explosions1. Human error can include mistakes, negligence, violations, or sabotage. Some examples of human errors that can lead to fires and explosions are:
Improper handling or storage of flammable or combustible materials
Failure to follow safety procedures or regulations
Lack of training or supervision
Poor maintenance or inspection of equipment or machinery
Ignoring or disabling alarms or warning systems
Smoking or using open flames near hazardous areas
Intentional or accidental ignition of explosives or incendiaries
To prevent or reduce the impact of human errors, industrial facilities should implement effective risk management strategies, such as:
Providing regular and adequate training and education for workers and managers Establishing and enforcing clear and consistent safety policies and rules Conducting thorough and frequent audits and inspections Installing and maintaining reliable fire protection systems and equipment Developing and practicing emergency response and evacuation plans Encouraging a positive safety culture and communication among all stakeholders


NEW QUESTION # 107
Which pure metal in its solid form in oxygen has the highest ignition temperature in degrees Fahrenheit?

  • A. Titanium
  • B. Aluminum
  • C. Zirconium
  • D. Potassium

Answer: A

Explanation:
titanium is the pure metal in its solid form in oxygen that has the highest ignition temperature in degrees Fahrenheit. The spontaneous-ignition temperature of titanium in the solid phase (below melting) is about 3020°F (1660°C) 1. Aluminum, potassium, and zirconium have lower ignition temperatures in the solid phase, ranging from 1292°F (700°C) to 1652°F (900°C) 23. Reference:
IGNITION OF METALS IN HIGH PRESSURE OXYGEN 2
Combustion of Metals in Oxygen-Enriched Atmospheres 3
High-temperature oxidation and ignition of metals 1


NEW QUESTION # 108
Which of the following can be used to create explosives?

  • A. PATP
  • B. ANFO
  • C. ARGO
  • D. TADP

Answer: C


NEW QUESTION # 109
......

Pass Your NFPA Exam with CFPS Exam Dumps: https://www.vceengine.com/CFPS-vce-test-engine.html

Verified CFPS Bundle Real Exam Dumps PDF: https://drive.google.com/open?id=1yOxAGWLm92f5EHUDrUZ3Sb-GvA_Bu6ZS